Vaillant Platinum Engineer in Finchley
Vaillant is the UK's best-selling boiler brand for good reason — their ecoTEC range combines proven reliability with the reassurance of British manufacturing. Every boiler sold in this country is built at Vaillant's Derbyshire facility, meaning parts are never far away and technical support speaks your language. As a Vaillant Platinum Certified Engineer, Hilton holds the highest level of manufacturer accreditation available.
Vaillant has manufactured in the UK since 1978. Their Belper facility produces every ecoTEC and ecoFIT sold in Britain — genuine UK manufacturing with German parent-company engineering standards.


Why Choose a Platinum Engineer?
Vaillant's Platinum tier isn't handed out freely. It represents the highest level of manufacturer recognition — and it comes with tangible benefits for you.
Extended Warranty Options
Platinum engineers can register installations for extended manufacturer warranties that standard Gas Safe engineers simply cannot offer. This isn't a marketing gimmick — it's a direct financial benefit on new installations.
Priority Technical Support
When a complex fault requires manufacturer input, Platinum engineers bypass the standard support queue. This translates directly to faster diagnosis and shorter repair times for you.
Ongoing Product Training
Maintaining Platinum status requires regular training on new models, firmware updates, and diagnostic procedures. This isn't a one-off qualification — it's a continuously maintained standard.
Proven Track Record
Platinum accreditation requires demonstrated installation quality and volume. Vaillant monitors customer satisfaction — engineers who don't maintain standards lose the accreditation.
The ecoTEC Range — Built in Britain
Every model in Vaillant's domestic range shares a common DNA — engineered in Germany, manufactured in Derbyshire, and supported by the UK's most extensive boiler parts network.
ecoFIT Pure
Vaillant's entry-range combi, but "entry" by Vaillant standards still means substantial engineering. The ecoFIT Pure uses a stainless steel heat exchanger and shares core components with the higher ecoTEC range. Built in Derbyshire alongside every other UK-market Vaillant.
ecoTEC Pro
The mid-range workhorse that has built Vaillant's UK reputation. The ecoTEC Pro offers proven reliability, good efficiency, and the straightforward serviceability that engineers appreciate. Millions installed across the UK — parts availability is unrivalled.
ecoTEC Plus
Vaillant's premium domestic range and the model we recommend most frequently for Finchley homes. The Plus adds advanced modulation (down to 16% of maximum output), compatibility with the vSMART thermostat for weather compensation, and the widest output range in the lineup.
Vaillant Fault Code Reference
Vaillant's diagnostic system uses fault codes prefixed with F for faults and S for status messages. Here are the codes we encounter most frequently across Finchley — and what they actually mean for your boiler.
Low Water Pressure
The system pressure has dropped below the minimum operating threshold (typically below 0.8 bar). Often caused by a slow leak somewhere in the system, a recently bled radiator, or a faulty pressure relief valve. While topping up via the filling loop is a temporary fix, persistent F22 faults indicate an underlying issue that needs professional investigation.
Flame Detection — Parasitic Flame
The flame sensing electrode is detecting ionisation current when the burner should be off. This is a safety-critical fault — the boiler suspects uncontrolled combustion and locks out immediately. Usually caused by moisture on the electrode, a failing PCB, or wiring issues. Do not attempt to override.
Ignition Failure
The most common Vaillant fault code. The boiler has attempted to ignite and failed. Causes range from simple (gas meter isolation, prepayment meter out of credit) to complex (gas valve failure, blocked condensate drain in freezing weather, ignition lead deterioration). A single occurrence after a power cut is normal; repeated F28 faults need diagnosis.
Flame Lost During Operation
The burner ignited successfully but the flame was lost before the cycle completed. Distinguished from F28 because ignition did occur. Typically indicates intermittent gas supply issues, flue terminal blockage (birds' nests are common in Finchley), or a failing gas valve that can't maintain flow under load.
Gas Valve Control Fault
The PCB has detected an irregularity in the gas valve control circuit. This is a safety lockout — the boiler will not attempt to fire. Usually indicates a failing gas valve actuator, damaged wiring loom, or PCB output stage fault. Requires specialist diagnostic equipment.
Gas Valve Shutoff Delay
The gas valve is not closing within the expected timeframe after a shutdown command. This is a serious safety fault — the boiler detects that gas may still be flowing after the burner should have stopped. The gas valve almost certainly requires replacement.
EEPROM Fault
The boiler's onboard memory (EEPROM) has a read/write error. The PCB cannot reliably store or retrieve operating parameters. While occasionally resolved by a power cycle, persistent F63 typically means the PCB needs replacement — a significant repair that warrants professional assessment.
Electronics / Sensor Fault
A catch-all code indicating the PCB has detected an anomaly in its sensor inputs — flow/return thermistors, pressure sensor, or other monitoring circuits. Requires systematic diagnosis to identify which specific sensor or circuit is responsible.
Pump / Pressure Sensor Fault
The boiler expects to see a pressure change when the pump starts — if the pressure sensor doesn't register movement, F75 appears. This can indicate pump seizure (common after summer inactivity), a failed pressure sensor, or air locks in the system. One of the most frequently misdiagnosed Vaillant faults.
Different Fault Code?
Vaillant boilers use dozens of diagnostic codes. Email us with your specific code and boiler model for expert guidance.
Report Fault CodeVaillant FAQ
Questions we hear regularly from Vaillant owners across Finchley and North London.
What does Vaillant Platinum Certified actually mean?
Platinum is Vaillant's highest tier of engineer accreditation. It requires demonstrated installation volume, ongoing product training, and customer feedback monitoring. Platinum engineers can offer extended warranties that standard Gas Safe engineers cannot, and have priority access to Vaillant's technical support team.
Are Vaillant boilers really made in the UK?
Yes, all Vaillant boilers sold in the UK market are manufactured at their facility in Belper, Derbyshire. This isn't just assembly — it's full production. The practical benefit is faster parts supply and shorter lead times compared to fully imported brands.
How long should a Vaillant boiler last?
With annual servicing, 12–18 years is typical for the ecoTEC range. The Plus models, with their higher-specification components, frequently reach 15+ years. We've serviced original ecoTEC Plus installations from the mid-2000s that are still running well.
Why does my Vaillant keep losing pressure?
Persistent pressure loss (needing to top up more than once every few months) indicates a leak somewhere in the system — not necessarily at the boiler itself. Common culprits include radiator valves, soldered joints, and the expansion vessel losing its charge. This needs professional investigation.
Can I use any thermostat with a Vaillant boiler?
While most standard thermostats will work for basic on/off control, Vaillant's own vSMART and sensoHOME thermostats communicate directly with the boiler via eBUS protocol, enabling modulation control and weather compensation. The efficiency gains from this integration are significant.
Is it worth upgrading from an ecoTEC Pro to a Plus?
If your Pro is nearing end-of-life, yes. The Plus's wider modulation range, better control integration, and longer warranty options make it the stronger investment. If your Pro is relatively new and running well, there's no urgency — it's a good boiler in its own right.
Need a Vaillant Specialist in Finchley?
Platinum Certified servicing, repairs, and installations across N12 and surrounding areas